Attempt to start an already started application results in an error message from AFM

XMLWordPrintable

      When selecting from the UI an already running application to bring it back into focus, after having switched to some other content, launching a new instance seems to be tentatively tried, although finally the application is brought back into focus without loss of functionality. As an example, being hvac  running already, trying to go back to hvac screen shows the following lines in the journal: 

      Mar 10 00:13:04 h3ulcb afbd-homescreen[3936]: qml: Activating: hvac
       Mar 10 00:13:04 h3ulcb afbd-agl-service-homescreen[3937]: INFO: [API homescreen] verb=[showWindow],appid=[hvac]. [/usr/src/debug/agl-service-homescreen/git-r0/git/src/hs-clientmanager.cpp:173,handleRequest]
       Mar 10 00:13:04 h3ulcb afbd-agl-service-homescreen[3937]: INFO: [API homescreen] service=afm-main verb=start, args=hvac. [/usr/src/debug/agl-service-homescreen/git-r0/git/src/hs-proxy.cpp:56,api_call]
       Mar 10 00:13:04 h3ulcb afm-system-daemon[3675]: ERROR: can't start system unit afm-appli-hvac-0.1-main@.service for uid 1001 [/usr/src/debug/af-main/master+gitAUTOINC+af8db35cc0-r0/git/src/afm-urun.c:268]